forked from Qortal/Brooklyn
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
87 lines
2.4 KiB
87 lines
2.4 KiB
.. SPDX-License-Identifier: GPL-2.0 |
|
|
|
Kernel driver max15301 |
|
====================== |
|
|
|
Supported chips: |
|
|
|
* Maxim MAX15301 |
|
|
|
Prefix: 'max15301', 'bmr461' |
|
|
|
Addresses scanned: - |
|
|
|
Datasheet: https://datasheets.maximintegrated.com/en/ds/MAX15301.pdf |
|
|
|
Author: Erik Rosen <[email protected]> |
|
|
|
|
|
Description |
|
----------- |
|
|
|
This driver supports hardware monitoring for Maxim MAX15301 controller chip and |
|
compatible modules. |
|
|
|
The driver is a client driver to the core PMBus driver. Please see |
|
Documentation/hwmon/pmbus.rst and Documentation.hwmon/pmbus-core for details |
|
on PMBus client drivers. |
|
|
|
|
|
Usage Notes |
|
----------- |
|
|
|
This driver does not auto-detect devices. You will have to instantiate the |
|
devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for |
|
details. |
|
|
|
|
|
Platform data support |
|
--------------------- |
|
|
|
The driver supports standard PMBus driver platform data. |
|
|
|
|
|
Module parameters |
|
----------------- |
|
|
|
delay |
|
----- |
|
|
|
The controller requires a minimum interval between I2C bus accesses. |
|
The default interval is set to 100 us. For manual override, the driver |
|
provides a writeable module parameter, 'delay', which can be used to |
|
set the interval to a value between 0 and 65,535 microseconds. |
|
|
|
|
|
Sysfs entries |
|
------------- |
|
|
|
The following attributes are supported. Limits are read-write; all other |
|
attributes are read-only. |
|
|
|
======================= ======================================================== |
|
in1_label "vin" |
|
in1_input Measured input voltage. |
|
in1_lcrit Critical minimum input voltage. |
|
in1_crit Critical maximum input voltage. |
|
in1_lcrit_alarm Input voltage critical low alarm. |
|
in1_crit_alarm Input voltage critical high alarm. |
|
|
|
in2_label "vout1" |
|
in2_input Measured output voltage. |
|
in2_lcrit Critical minimum output Voltage. |
|
in2_crit Critical maximum output voltage. |
|
in2_lcrit_alarm Critical output voltage critical low alarm. |
|
in2_crit_alarm Critical output voltage critical high alarm. |
|
|
|
curr1_label "iout1" |
|
curr1_input Measured output current. |
|
curr1_crit Critical maximum output current. |
|
curr1_crit_alarm Output current critical high alarm. |
|
|
|
temp1_input Measured maximum temperature of all phases. |
|
temp1_max Maximum temperature limit. |
|
temp1_max_alarm High temperature alarm. |
|
temp1_crit Critical maximum temperature limit. |
|
temp1_crit_alarm Critical maximum temperature alarm. |
|
======================= ========================================================
|
|
|