Kernel driver ds620 |
|
=================== |
|
|
|
Supported chips: |
|
|
|
* Dallas Semiconductor DS620 |
|
|
|
Prefix: 'ds620' |
|
|
|
Datasheet: Publicly available at the Dallas Semiconductor website |
|
|
|
http://www.dalsemi.com/ |
|
|
|
Authors: |
|
Roland Stigge <[email protected]> |
|
based on ds1621.c by |
|
Christian W. Zuckschwerdt <[email protected]> |
|
|
|
Description |
|
----------- |
|
|
|
The DS620 is a (one instance) digital thermometer and thermostat. It has both |
|
high and low temperature limits which can be user defined (i.e. programmed |
|
into non-volatile on-chip registers). Temperature range is -55 degree Celsius |
|
to +125. Between 0 and 70 degree Celsius, accuracy is 0.5 Kelvin. The value |
|
returned via sysfs displays post decimal positions. |
|
|
|
The thermostat function works as follows: When configured via platform_data |
|
(struct ds620_platform_data) .pomode == 0 (default), the thermostat output pin |
|
PO is always low. If .pomode == 1, the thermostat is in PO_LOW mode. I.e., the |
|
output pin PO becomes active when the temperature falls below temp1_min and |
|
stays active until the temperature goes above temp1_max. |
|
|
|
Likewise, with .pomode == 2, the thermostat is in PO_HIGH mode. I.e., the PO |
|
output pin becomes active when the temperature goes above temp1_max and stays |
|
active until the temperature falls below temp1_min. |
|
|
|
The PO output pin of the DS620 operates active-low.
|
|
|