.. SPDX-License-Identifier: GPL-2.0-or-later |
|
|
|
.. include:: <isonum.txt> |
|
|
|
Kernel driver dell-smm-hwmon |
|
============================ |
|
|
|
:Copyright: |copy| 2002-2005 Massimo Dal Zotto <[email protected]> |
|
:Copyright: |copy| 2019 Giovanni Mascellani <[email protected]> |
|
|
|
Description |
|
----------- |
|
|
|
On many Dell laptops the System Management Mode (SMM) BIOS can be |
|
queried for the status of fans and temperature sensors. Userspace |
|
utilities like ``sensors`` can be used to return the readings. The |
|
userspace suite `i8kutils`__ can also be used to read the sensors and |
|
automatically adjust fan speed (please notice that it currently uses |
|
the deprecated ``/proc/i8k`` interface). |
|
|
|
__ https://github.com/vitorafsr/i8kutils |
|
|
|
``sysfs`` interface |
|
------------------- |
|
|
|
Temperature sensors and fans can be queried and set via the standard |
|
``hwmon`` interface on ``sysfs``, under the directory |
|
``/sys/class/hwmon/hwmonX`` for some value of ``X`` (search for the |
|
``X`` such that ``/sys/class/hwmon/hwmonX/name`` has content |
|
``dell_smm``). A number of other attributes can be read or written: |
|
|
|
=============================== ======= ======================================= |
|
Name Perm Description |
|
=============================== ======= ======================================= |
|
fan[1-3]_input RO Fan speed in RPM. |
|
fan[1-3]_label RO Fan label. |
|
fan[1-3]_min RO Minimal Fan speed in RPM |
|
fan[1-3]_max RO Maximal Fan speed in RPM |
|
fan[1-3]_target RO Expected Fan speed in RPM |
|
pwm[1-3] RW Control the fan PWM duty-cycle. |
|
pwm1_enable WO Enable or disable automatic BIOS fan |
|
control (not supported on all laptops, |
|
see below for details). |
|
temp[1-10]_input RO Temperature reading in milli-degrees |
|
Celsius. |
|
temp[1-10]_label RO Temperature sensor label. |
|
=============================== ======= ======================================= |
|
|
|
Disabling automatic BIOS fan control |
|
------------------------------------ |
|
|
|
On some laptops the BIOS automatically sets fan speed every few |
|
seconds. Therefore the fan speed set by mean of this driver is quickly |
|
overwritten. |
|
|
|
There is experimental support for disabling automatic BIOS fan |
|
control, at least on laptops where the corresponding SMM command is |
|
known, by writing the value ``1`` in the attribute ``pwm1_enable`` |
|
(writing ``2`` enables automatic BIOS control again). Even if you have |
|
more than one fan, all of them are set to either enabled or disabled |
|
automatic fan control at the same time and, notwithstanding the name, |
|
``pwm1_enable`` sets automatic control for all fans. |
|
|
|
If ``pwm1_enable`` is not available, then it means that SMM codes for |
|
enabling and disabling automatic BIOS fan control are not whitelisted |
|
for your hardware. It is possible that codes that work for other |
|
laptops actually work for yours as well, or that you have to discover |
|
new codes. |
|
|
|
Check the list ``i8k_whitelist_fan_control`` in file |
|
``drivers/hwmon/dell-smm-hwmon.c`` in the kernel tree: as a first |
|
attempt you can try to add your machine and use an already-known code |
|
pair. If, after recompiling the kernel, you see that ``pwm1_enable`` |
|
is present and works (i.e., you can manually control the fan speed), |
|
then please submit your finding as a kernel patch, so that other users |
|
can benefit from it. Please see |
|
:ref:`Documentation/process/submitting-patches.rst <submittingpatches>` |
|
for information on submitting patches. |
|
|
|
If no known code works on your machine, you need to resort to do some |
|
probing, because unfortunately Dell does not publish datasheets for |
|
its SMM. You can experiment with the code in `this repository`__ to |
|
probe the BIOS on your machine and discover the appropriate codes. |
|
|
|
__ https://github.com/clopez/dellfan/ |
|
|
|
Again, when you find new codes, we'd be happy to have your patches! |
|
|
|
Module parameters |
|
----------------- |
|
|
|
* force:bool |
|
Force loading without checking for supported |
|
models. (default: 0) |
|
|
|
* ignore_dmi:bool |
|
Continue probing hardware even if DMI data does not |
|
match. (default: 0) |
|
|
|
* restricted:bool |
|
Allow fan control only to processes with the |
|
``CAP_SYS_ADMIN`` capability set or processes run |
|
as root when using the legacy ``/proc/i8k`` |
|
interface. In this case normal users will be able |
|
to read temperature and fan status but not to |
|
control the fan. If your notebook is shared with |
|
other users and you don't trust them you may want |
|
to use this option. (default: 1, only available |
|
with ``CONFIG_I8K``) |
|
|
|
* power_status:bool |
|
Report AC status in ``/proc/i8k``. (default: 0, |
|
only available with ``CONFIG_I8K``) |
|
|
|
* fan_mult:uint |
|
Factor to multiply fan speed with. (default: |
|
autodetect) |
|
|
|
* fan_max:uint |
|
Maximum configurable fan speed. (default: |
|
autodetect) |
|
|
|
Legacy ``/proc`` interface |
|
-------------------------- |
|
|
|
.. warning:: This interface is obsolete and deprecated and should not |
|
used in new applications. This interface is only |
|
available when kernel is compiled with option |
|
``CONFIG_I8K``. |
|
|
|
The information provided by the kernel driver can be accessed by |
|
simply reading the ``/proc/i8k`` file. For example:: |
|
|
|
$ cat /proc/i8k |
|
1.0 A17 2J59L02 52 2 1 8040 6420 1 2 |
|
|
|
The fields read from ``/proc/i8k`` are:: |
|
|
|
1.0 A17 2J59L02 52 2 1 8040 6420 1 2 |
|
| | | | | | | | | | |
|
| | | | | | | | | +------- 10. buttons status |
|
| | | | | | | | +--------- 9. AC status |
|
| | | | | | | +-------------- 8. fan0 RPM |
|
| | | | | | +------------------- 7. fan1 RPM |
|
| | | | | +--------------------- 6. fan0 status |
|
| | | | +----------------------- 5. fan1 status |
|
| | | +-------------------------- 4. temp0 reading (Celsius) |
|
| | +---------------------------------- 3. Dell service tag (later known as 'serial number') |
|
| +-------------------------------------- 2. BIOS version |
|
+------------------------------------------ 1. /proc/i8k format version |
|
|
|
A negative value, for example -22, indicates that the BIOS doesn't |
|
return the corresponding information. This is normal on some |
|
models/BIOSes. |
|
|
|
For performance reasons the ``/proc/i8k`` doesn't report by default |
|
the AC status since this SMM call takes a long time to execute and is |
|
not really needed. If you want to see the ac status in ``/proc/i8k`` |
|
you must explictitly enable this option by passing the |
|
``power_status=1`` parameter to insmod. If AC status is not |
|
available -1 is printed instead. |
|
|
|
The driver provides also an ioctl interface which can be used to |
|
obtain the same information and to control the fan status. The ioctl |
|
interface can be accessed from C programs or from shell using the |
|
i8kctl utility. See the source file of ``i8kutils`` for more |
|
information on how to use the ioctl interface.
|
|
|