%YAML 1.2 |
|
--- |
|
$id: http://devicetree.org/schemas/regulator/regulator.yaml# |
|
$schema: http://devicetree.org/meta-schemas/core.yaml# |
|
|
|
title: Voltage/Current Regulators |
|
|
|
maintainers: |
|
- Liam Girdwood <[email protected]> |
|
- Mark Brown <[email protected]> |
|
|
|
properties: |
|
regulator-name: |
|
description: A string used as a descriptive name for regulator outputs |
|
$ref: "/schemas/types.yaml#/definitions/string" |
|
|
|
regulator-min-microvolt: |
|
description: smallest voltage consumers may set |
|
|
|
regulator-max-microvolt: |
|
description: largest voltage consumers may set |
|
|
|
regulator-microvolt-offset: |
|
description: Offset applied to voltages to compensate for voltage drops |
|
$ref: "/schemas/types.yaml#/definitions/uint32" |
|
|
|
regulator-min-microamp: |
|
description: smallest current consumers may set |
|
|
|
regulator-max-microamp: |
|
description: largest current consumers may set |
|
|
|
regulator-input-current-limit-microamp: |
|
description: maximum input current regulator allows |
|
|
|
regulator-always-on: |
|
description: boolean, regulator should never be disabled |
|
type: boolean |
|
|
|
regulator-boot-on: |
|
description: bootloader/firmware enabled regulator. |
|
It's expected that this regulator was left on by the bootloader. |
|
If the bootloader didn't leave it on then OS should turn it on |
|
at boot but shouldn't prevent it from being turned off later. |
|
This property is intended to only be used for regulators where |
|
software cannot read the state of the regulator. |
|
type: boolean |
|
|
|
regulator-allow-bypass: |
|
description: allow the regulator to go into bypass mode |
|
type: boolean |
|
|
|
regulator-allow-set-load: |
|
description: allow the regulator performance level to be configured |
|
type: boolean |
|
|
|
regulator-ramp-delay: |
|
description: ramp delay for regulator(in uV/us) For hardware which supports |
|
disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay |
|
= <0>) for disabling ramp delay. |
|
$ref: "/schemas/types.yaml#/definitions/uint32" |
|
|
|
regulator-enable-ramp-delay: |
|
description: The time taken, in microseconds, for the supply rail to |
|
reach the target voltage, plus/minus whatever tolerance the board |
|
design requires. This property describes the total system ramp time |
|
required due to the combination of internal ramping of the regulator |
|
itself, and board design issues such as trace capacitance and load |
|
on the supply. |
|
$ref: "/schemas/types.yaml#/definitions/uint32" |
|
|
|
regulator-settling-time-us: |
|
description: Settling time, in microseconds, for voltage change if regulator |
|
have the constant time for any level voltage change. This is useful |
|
when regulator have exponential voltage change. |
|
|
|
regulator-settling-time-up-us: |
|
description: Settling time, in microseconds, for voltage increase if |
|
the regulator needs a constant time to settle after voltage increases |
|
of any level. This is useful for regulators with exponential voltage |
|
changes. |
|
|
|
regulator-settling-time-down-us: |
|
description: Settling time, in microseconds, for voltage decrease if |
|
the regulator needs a constant time to settle after voltage decreases |
|
of any level. This is useful for regulators with exponential voltage |
|
changes. |
|
|
|
regulator-soft-start: |
|
description: Enable soft start so that voltage ramps slowly |
|
type: boolean |
|
|
|
regulator-initial-mode: |
|
description: initial operating mode. The set of possible operating modes |
|
depends on the capabilities of every hardware so each device binding |
|
documentation explains which values the regulator supports. |
|
$ref: "/schemas/types.yaml#/definitions/uint32" |
|
|
|
regulator-allowed-modes: |
|
description: list of operating modes that software is allowed to configure |
|
for the regulator at run-time. Elements may be specified in any order. |
|
The set of possible operating modes depends on the capabilities of |
|
every hardware so each device binding document explains which values |
|
the regulator supports. |
|
$ref: "/schemas/types.yaml#/definitions/uint32-array" |
|
|
|
regulator-system-load: |
|
description: Load in uA present on regulator that is not captured by |
|
any consumer request. |
|
$ref: "/schemas/types.yaml#/definitions/uint32" |
|
|
|
regulator-pull-down: |
|
description: Enable pull down resistor when the regulator is disabled. |
|
type: boolean |
|
|
|
regulator-over-current-protection: |
|
description: Enable over current protection. |
|
type: boolean |
|
|
|
regulator-oc-protection-microamp: |
|
description: Set over current protection limit. This is a limit where |
|
hardware performs emergency shutdown. Zero can be passed to disable |
|
protection and value '1' indicates that protection should be enabled but |
|
limit setting can be omitted. |
|
|
|
regulator-oc-error-microamp: |
|
description: Set over current error limit. This is a limit where part of |
|
the hardware propably is malfunctional and damage prevention is requested. |
|
Zero can be passed to disable error detection and value '1' indicates |
|
that detection should be enabled but limit setting can be omitted. |
|
|
|
regulator-oc-warn-microamp: |
|
description: Set over current warning limit. This is a limit where hardware |
|
is assumed still to be functional but approaching limit where it gets |
|
damaged. Recovery actions should be initiated. Zero can be passed to |
|
disable detection and value '1' indicates that detection should |
|
be enabled but limit setting can be omitted. |
|
|
|
regulator-ov-protection-microvolt: |
|
description: Set over voltage protection limit. This is a limit where |
|
hardware performs emergency shutdown. Zero can be passed to disable |
|
protection and value '1' indicates that protection should be enabled but |
|
limit setting can be omitted. Limit is given as microvolt offset from |
|
voltage set to regulator. |
|
|
|
regulator-ov-error-microvolt: |
|
description: Set over voltage error limit. This is a limit where part of |
|
the hardware propably is malfunctional and damage prevention is requested |
|
Zero can be passed to disable error detection and value '1' indicates |
|
that detection should be enabled but limit setting can be omitted. Limit |
|
is given as microvolt offset from voltage set to regulator. |
|
|
|
regulator-ov-warn-microvolt: |
|
description: Set over voltage warning limit. This is a limit where hardware |
|
is assumed still to be functional but approaching limit where it gets |
|
damaged. Recovery actions should be initiated. Zero can be passed to |
|
disable detection and value '1' indicates that detection should |
|
be enabled but limit setting can be omitted. Limit is given as microvolt |
|
offset from voltage set to regulator. |
|
|
|
regulator-uv-protection-microvolt: |
|
description: Set over under voltage protection limit. This is a limit where |
|
hardware performs emergency shutdown. Zero can be passed to disable |
|
protection and value '1' indicates that protection should be enabled but |
|
limit setting can be omitted. Limit is given as microvolt offset from |
|
voltage set to regulator. |
|
|
|
regulator-uv-error-microvolt: |
|
description: Set under voltage error limit. This is a limit where part of |
|
the hardware propably is malfunctional and damage prevention is requested |
|
Zero can be passed to disable error detection and value '1' indicates |
|
that detection should be enabled but limit setting can be omitted. Limit |
|
is given as microvolt offset from voltage set to regulator. |
|
|
|
regulator-uv-warn-microvolt: |
|
description: Set over under voltage warning limit. This is a limit where |
|
hardware is assumed still to be functional but approaching limit where |
|
it gets damaged. Recovery actions should be initiated. Zero can be passed |
|
to disable detection and value '1' indicates that detection should |
|
be enabled but limit setting can be omitted. Limit is given as microvolt |
|
offset from voltage set to regulator. |
|
|
|
regulator-temp-protection-kelvin: |
|
description: Set over temperature protection limit. This is a limit where |
|
hardware performs emergency shutdown. Zero can be passed to disable |
|
protection and value '1' indicates that protection should be enabled but |
|
limit setting can be omitted. |
|
|
|
regulator-temp-error-kelvin: |
|
description: Set over temperature error limit. This is a limit where part of |
|
the hardware propably is malfunctional and damage prevention is requested |
|
Zero can be passed to disable error detection and value '1' indicates |
|
that detection should be enabled but limit setting can be omitted. |
|
|
|
regulator-temp-warn-kelvin: |
|
description: Set over temperature warning limit. This is a limit where |
|
hardware is assumed still to be functional but approaching limit where it |
|
gets damaged. Recovery actions should be initiated. Zero can be passed to |
|
disable detection and value '1' indicates that detection should |
|
be enabled but limit setting can be omitted. |
|
|
|
regulator-active-discharge: |
|
description: | |
|
tristate, enable/disable active discharge of regulators. The values are: |
|
0: Disable active discharge. |
|
1: Enable active discharge. |
|
Absence of this property will leave configuration to default. |
|
$ref: "/schemas/types.yaml#/definitions/uint32" |
|
enum: [0, 1] |
|
|
|
regulator-coupled-with: |
|
description: Regulators with which the regulator is coupled. The linkage |
|
is 2-way - all coupled regulators should be linked with each other. |
|
A regulator should not be coupled with its supplier. |
|
$ref: "/schemas/types.yaml#/definitions/phandle-array" |
|
items: |
|
maxItems: 1 |
|
|
|
regulator-coupled-max-spread: |
|
description: Array of maximum spread between voltages of coupled regulators |
|
in microvolts, each value in the array relates to the corresponding |
|
couple specified by the regulator-coupled-with property. |
|
$ref: "/schemas/types.yaml#/definitions/uint32-array" |
|
|
|
regulator-max-step-microvolt: |
|
description: Maximum difference between current and target voltages |
|
that can be changed safely in a single step. |
|
|
|
patternProperties: |
|
".*-supply$": |
|
description: Input supply phandle(s) for this node |
|
|
|
regulator-state-(standby|mem|disk): |
|
type: object |
|
description: |
|
sub-nodes for regulator state in Standby, Suspend-to-RAM, and |
|
Suspend-to-DISK modes. Equivalent with standby, mem, and disk Linux |
|
sleep states. |
|
|
|
properties: |
|
regulator-on-in-suspend: |
|
description: regulator should be on in suspend state. |
|
type: boolean |
|
|
|
regulator-off-in-suspend: |
|
description: regulator should be off in suspend state. |
|
type: boolean |
|
|
|
regulator-suspend-min-microvolt: |
|
description: minimum voltage may be set in suspend state. |
|
|
|
regulator-suspend-max-microvolt: |
|
description: maximum voltage may be set in suspend state. |
|
|
|
regulator-suspend-microvolt: |
|
description: the default voltage which regulator would be set in |
|
suspend. This property is now deprecated, instead setting voltage |
|
for suspend mode via the API which regulator driver provides is |
|
recommended. |
|
|
|
regulator-changeable-in-suspend: |
|
description: whether the default voltage and the regulator on/off |
|
in suspend can be changed in runtime. |
|
type: boolean |
|
|
|
regulator-mode: |
|
description: operating mode in the given suspend state. The set |
|
of possible operating modes depends on the capabilities of every |
|
hardware so the valid modes are documented on each regulator device |
|
tree binding document. |
|
$ref: "/schemas/types.yaml#/definitions/uint32" |
|
|
|
additionalProperties: false |
|
|
|
additionalProperties: true |
|
|
|
examples: |
|
- | |
|
xyzreg: regulator { |
|
regulator-min-microvolt = <1000000>; |
|
regulator-max-microvolt = <2500000>; |
|
regulator-always-on; |
|
vin-supply = <&vin>; |
|
|
|
regulator-state-mem { |
|
regulator-on-in-suspend; |
|
}; |
|
}; |
|
|
|
...
|
|
|