# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) |
|
%YAML 1.2 |
|
--- |
|
$id: http://devicetree.org/schemas/thermal/socionext,uniphier-thermal.yaml# |
|
$schema: http://devicetree.org/meta-schemas/core.yaml# |
|
|
|
title: Socionext UniPhier thermal monitor |
|
|
|
description: | |
|
This describes the devicetree bindings for thermal monitor supported by |
|
PVT(Process, Voltage and Temperature) monitoring unit implemented on |
|
Socionext UniPhier SoCs. |
|
|
|
maintainers: |
|
- Kunihiko Hayashi <[email protected]> |
|
|
|
properties: |
|
compatible: |
|
enum: |
|
- socionext,uniphier-pxs2-thermal |
|
- socionext,uniphier-ld20-thermal |
|
- socionext,uniphier-pxs3-thermal |
|
|
|
interrupts: |
|
maxItems: 1 |
|
|
|
"#thermal-sensor-cells": |
|
const: 0 |
|
|
|
socionext,tmod-calibration: |
|
$ref: /schemas/types.yaml#/definitions/uint32-array |
|
maxItems: 2 |
|
description: |
|
A pair of calibrated values referred from PVT, in case that the values |
|
aren't set on SoC, like a reference board. |
|
|
|
required: |
|
- compatible |
|
- interrupts |
|
- "#thermal-sensor-cells" |
|
|
|
additionalProperties: false |
|
|
|
examples: |
|
- | |
|
// The UniPhier thermal should be a subnode of a "syscon" compatible node. |
|
|
|
sysctrl@61840000 { |
|
compatible = "socionext,uniphier-ld20-sysctrl", |
|
"simple-mfd", "syscon"; |
|
reg = <0x61840000 0x10000>; |
|
|
|
pvtctl: thermal { |
|
compatible = "socionext,uniphier-ld20-thermal"; |
|
interrupts = <0 3 1>; |
|
#thermal-sensor-cells = <0>; |
|
}; |
|
};
|
|
|