* Dialog DA9062 Power Management Integrated Circuit (PMIC) |
|
|
|
Product information for the DA9062 and DA9061 devices can be found here: |
|
- https://www.dialog-semiconductor.com/products/da9062 |
|
- https://www.dialog-semiconductor.com/products/da9061 |
|
|
|
The DA9062 PMIC consists of: |
|
|
|
Device Supply Names Description |
|
------ ------------ ----------- |
|
da9062-regulator : : LDOs & BUCKs |
|
da9062-rtc : : Real-Time Clock |
|
da9062-onkey : : On Key |
|
da9062-watchdog : : Watchdog Timer |
|
da9062-thermal : : Thermal |
|
da9062-gpio : : GPIOs |
|
|
|
The DA9061 PMIC consists of: |
|
|
|
Device Supply Names Description |
|
------ ------------ ----------- |
|
da9062-regulator : : LDOs & BUCKs |
|
da9062-onkey : : On Key |
|
da9062-watchdog : : Watchdog Timer |
|
da9062-thermal : : Thermal |
|
|
|
====== |
|
|
|
Required properties: |
|
|
|
- compatible : Should be |
|
"dlg,da9062" for DA9062 |
|
"dlg,da9061" for DA9061 |
|
- reg : Specifies the I2C slave address (this defaults to 0x58 but it can be |
|
modified to match the chip's OTP settings). |
|
- interrupts : IRQ line information. |
|
- interrupt-controller |
|
|
|
See Documentation/devicetree/bindings/interrupt-controller/interrupts.txt for |
|
further information on IRQ bindings. |
|
|
|
Optional properties: |
|
|
|
- gpio-controller : Marks the device as a gpio controller. |
|
- #gpio-cells : Should be two. The first cell is the pin number and the |
|
second cell is used to specify the gpio polarity. |
|
|
|
See Documentation/devicetree/bindings/gpio/gpio.txt for further information on |
|
GPIO bindings. |
|
|
|
Sub-nodes: |
|
|
|
- regulators : This node defines the settings for the LDOs and BUCKs. |
|
The DA9062 regulators are bound using their names listed below: |
|
|
|
buck1 : BUCK_1 |
|
buck2 : BUCK_2 |
|
buck3 : BUCK_3 |
|
buck4 : BUCK_4 |
|
ldo1 : LDO_1 |
|
ldo2 : LDO_2 |
|
ldo3 : LDO_3 |
|
ldo4 : LDO_4 |
|
|
|
The DA9061 regulators are bound using their names listed below: |
|
|
|
buck1 : BUCK_1 |
|
buck2 : BUCK_2 |
|
buck3 : BUCK_3 |
|
ldo1 : LDO_1 |
|
ldo2 : LDO_2 |
|
ldo3 : LDO_3 |
|
ldo4 : LDO_4 |
|
|
|
The component follows the standard regulator framework and the bindings |
|
details of individual regulator device can be found in: |
|
Documentation/devicetree/bindings/regulator/regulator.txt |
|
|
|
regulator-initial-mode may be specified for buck regulators using mode values |
|
from include/dt-bindings/regulator/dlg,da9063-regulator.h. |
|
|
|
- rtc : This node defines settings required for the Real-Time Clock associated |
|
with the DA9062. There are currently no entries in this binding, however |
|
compatible = "dlg,da9062-rtc" should be added if a node is created. |
|
|
|
- onkey : See ../input/da9062-onkey.txt |
|
|
|
- watchdog: See ../watchdog/da9062-watchdog.txt |
|
|
|
- thermal : See ../thermal/da9062-thermal.txt |
|
|
|
Example: |
|
|
|
pmic0: da9062@58 { |
|
compatible = "dlg,da9062"; |
|
reg = <0x58>; |
|
interrupt-parent = <&gpio6>; |
|
interrupts = <11 IRQ_TYPE_LEVEL_LOW>; |
|
interrupt-controller; |
|
|
|
rtc { |
|
compatible = "dlg,da9062-rtc"; |
|
}; |
|
|
|
regulators { |
|
DA9062_BUCK1: buck1 { |
|
regulator-name = "BUCK1"; |
|
regulator-min-microvolt = <300000>; |
|
regulator-max-microvolt = <1570000>; |
|
regulator-min-microamp = <500000>; |
|
regulator-max-microamp = <2000000>; |
|
regulator-initial-mode = <DA9063_BUCK_MODE_SYNC>; |
|
regulator-boot-on; |
|
}; |
|
DA9062_LDO1: ldo1 { |
|
regulator-name = "LDO_1"; |
|
regulator-min-microvolt = <900000>; |
|
regulator-max-microvolt = <3600000>; |
|
regulator-boot-on; |
|
}; |
|
}; |
|
}; |
|
|
|
|