What: /sys/bus/iio/devices/iio:deviceX/in_count_count_mode_available |
|
What: /sys/bus/iio/devices/iio:deviceX/in_count_noise_error_available |
|
What: /sys/bus/iio/devices/iio:deviceX/in_count_quadrature_mode_available |
|
What: /sys/bus/iio/devices/iio:deviceX/in_index_index_polarity_available |
|
What: /sys/bus/iio/devices/iio:deviceX/in_index_synchronous_mode_available |
|
KernelVersion: 4.10 |
|
Contact: [email protected] |
|
Description: |
|
This interface is deprecated; please use the Counter subsystem. |
|
|
|
Discrete set of available values for the respective counter |
|
configuration are listed in this file. |
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_countY_count_mode |
|
KernelVersion: 4.10 |
|
Contact: [email protected] |
|
Description: |
|
This interface is deprecated; please use the Counter subsystem. |
|
|
|
Count mode for channel Y. Four count modes are available: |
|
normal, range limit, non-recycle, and modulo-n. The preset value |
|
for channel Y is used by the count mode where required. |
|
|
|
Normal: |
|
Counting is continuous in either direction. |
|
|
|
Range Limit: |
|
An upper or lower limit is set, mimicking limit switches |
|
in the mechanical counterpart. The upper limit is set to |
|
the preset value, while the lower limit is set to 0. The |
|
counter freezes at count = preset when counting up, and |
|
at count = 0 when counting down. At either of these |
|
limits, the counting is resumed only when the count |
|
direction is reversed. |
|
|
|
Non-recycle: |
|
Counter is disabled whenever a 24-bit count overflow or |
|
underflow takes place. The counter is re-enabled when a |
|
new count value is loaded to the counter via a preset |
|
operation or write to raw. |
|
|
|
Modulo-N: |
|
A count boundary is set between 0 and the preset value. |
|
The counter is reset to 0 at count = preset when |
|
counting up, while the counter is set to the preset |
|
value at count = 0 when counting down; the counter does |
|
not freeze at the bundary points, but counts |
|
continuously throughout. |
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_countY_noise_error |
|
KernelVersion: 4.10 |
|
Contact: [email protected] |
|
Description: |
|
This interface is deprecated; please use the Counter subsystem. |
|
|
|
Read-only attribute that indicates whether excessive noise is |
|
present at the channel Y count inputs in quadrature clock mode; |
|
irrelevant in non-quadrature clock mode. |
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_countY_preset |
|
KernelVersion: 4.10 |
|
Contact: [email protected] |
|
Description: |
|
This interface is deprecated; please use the Counter subsystem. |
|
|
|
If the counter device supports preset registers, the preset |
|
count for channel Y is provided by this attribute. |
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_countY_quadrature_mode |
|
KernelVersion: 4.10 |
|
Contact: [email protected] |
|
Description: |
|
This interface is deprecated; please use the Counter subsystem. |
|
|
|
Configure channel Y counter for non-quadrature or quadrature |
|
clock mode. Selecting non-quadrature clock mode will disable |
|
synchronous load mode. In quadrature clock mode, the channel Y |
|
scale attribute selects the encoder phase division (scale of 1 |
|
selects full-cycle, scale of 0.5 selects half-cycle, scale of |
|
0.25 selects quarter-cycle) processed by the channel Y counter. |
|
|
|
Non-quadrature: |
|
The filter and decoder circuit are bypassed. Encoder A |
|
input serves as the count input and B as the UP/DOWN |
|
direction control input, with B = 1 selecting UP Count |
|
mode and B = 0 selecting Down Count mode. |
|
|
|
Quadrature: |
|
Encoder A and B inputs are digitally filtered and |
|
decoded for UP/DN clock. |
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_countY_set_to_preset_on_index |
|
KernelVersion: 4.10 |
|
Contact: [email protected] |
|
Description: |
|
This interface is deprecated; please use the Counter subsystem. |
|
|
|
Whether to set channel Y counter with channel Y preset value |
|
when channel Y index input is active, or continuously count. |
|
Valid attribute values are boolean. |
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_indexY_index_polarity |
|
KernelVersion: 4.10 |
|
Contact: [email protected] |
|
Description: |
|
This interface is deprecated; please use the Counter subsystem. |
|
|
|
Active level of channel Y index input; irrelevant in |
|
non-synchronous load mode. |
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_indexY_synchronous_mode |
|
KernelVersion: 4.10 |
|
Contact: [email protected] |
|
Description: |
|
This interface is deprecated; please use the Counter subsystem. |
|
|
|
Configure channel Y counter for non-synchronous or synchronous |
|
load mode. Synchronous load mode cannot be selected in |
|
non-quadrature clock mode. |
|
|
|
Non-synchronous: |
|
A logic low level is the active level at this index |
|
input. The index function (as enabled via |
|
set_to_preset_on_index) is performed directly on the |
|
active level of the index input. |
|
|
|
Synchronous: |
|
Intended for interfacing with encoder Index output in |
|
quadrature clock mode. The active level is configured |
|
via index_polarity. The index function (as enabled via |
|
set_to_preset_on_index) is performed synchronously with |
|
the quadrature clock on the active level of the index |
|
input.
|
|
|