Kernel driver max6639 |
|
===================== |
|
|
|
Supported chips: |
|
|
|
* Maxim MAX6639 |
|
|
|
Prefix: 'max6639' |
|
|
|
Addresses scanned: I2C 0x2c, 0x2e, 0x2f |
|
|
|
Datasheet: https://datasheets.maximintegrated.com/en/ds/MAX6639-MAX6639F.pdf |
|
|
|
Authors: |
|
- He Changqing <[email protected]> |
|
- Roland Stigge <[email protected]> |
|
|
|
Description |
|
----------- |
|
|
|
This driver implements support for the Maxim MAX6639. This chip is a 2-channel |
|
temperature monitor with dual PWM fan speed controller. It can monitor its own |
|
temperature and one external diode-connected transistor or two external |
|
diode-connected transistors. |
|
|
|
The following device attributes are implemented via sysfs: |
|
|
|
====================== ==== =================================================== |
|
Attribute R/W Contents |
|
====================== ==== =================================================== |
|
temp1_input R Temperature channel 1 input (0..150 C) |
|
temp2_input R Temperature channel 2 input (0..150 C) |
|
temp1_fault R Temperature channel 1 diode fault |
|
temp2_fault R Temperature channel 2 diode fault |
|
temp1_max RW Set THERM temperature for input 1 |
|
(in C, see datasheet) |
|
temp2_max RW Set THERM temperature for input 2 |
|
temp1_crit RW Set ALERT temperature for input 1 |
|
temp2_crit RW Set ALERT temperature for input 2 |
|
temp1_emergency RW Set OT temperature for input 1 |
|
(in C, see datasheet) |
|
temp2_emergency RW Set OT temperature for input 2 |
|
pwm1 RW Fan 1 target duty cycle (0..255) |
|
pwm2 RW Fan 2 target duty cycle (0..255) |
|
fan1_input R TACH1 fan tachometer input (in RPM) |
|
fan2_input R TACH2 fan tachometer input (in RPM) |
|
fan1_fault R Fan 1 fault |
|
fan2_fault R Fan 2 fault |
|
temp1_max_alarm R Alarm on THERM temperature on channel 1 |
|
temp2_max_alarm R Alarm on THERM temperature on channel 2 |
|
temp1_crit_alarm R Alarm on ALERT temperature on channel 1 |
|
temp2_crit_alarm R Alarm on ALERT temperature on channel 2 |
|
temp1_emergency_alarm R Alarm on OT temperature on channel 1 |
|
temp2_emergency_alarm R Alarm on OT temperature on channel 2 |
|
====================== ==== ===================================================
|
|
|