DT bindings for the Renesas R-Mobile System Controller |
|
|
|
== System Controller Node == |
|
|
|
The R-Mobile System Controller provides the following functions: |
|
- Boot mode management, |
|
- Reset generation, |
|
- Power management. |
|
|
|
Required properties: |
|
- compatible: Should be "renesas,sysc-<soctype>", "renesas,sysc-rmobile" as |
|
fallback. |
|
Examples with soctypes are: |
|
- "renesas,sysc-r8a73a4" (R-Mobile APE6) |
|
- "renesas,sysc-r8a7740" (R-Mobile A1) |
|
- "renesas,sysc-sh73a0" (SH-Mobile AG5) |
|
- reg: Two address start and address range blocks for the device: |
|
- The first block refers to the normally accessible registers, |
|
- the second block refers to the registers protected by the HPB |
|
semaphore. |
|
|
|
Optional nodes: |
|
- pm-domains: This node contains a hierarchy of PM domain nodes, which should |
|
match the Power Area Hierarchy in the Power Domain Specifications section of |
|
the device's datasheet. |
|
|
|
|
|
== PM Domain Nodes == |
|
|
|
Each of the PM domain nodes represents a PM domain, as documented by the |
|
generic PM domain bindings in |
|
Documentation/devicetree/bindings/power/power-domain.yaml. |
|
|
|
The nodes should be named by the real power area names, and thus their names |
|
should be unique. |
|
|
|
Required properties: |
|
- #power-domain-cells: Must be 0. |
|
|
|
Optional properties: |
|
- reg: If the PM domain is not always-on, this property must contain the bit |
|
index number for the corresponding power area in the various Power |
|
Control and Status Registers. The parent's node must contain the |
|
following two properties: |
|
- #address-cells: Must be 1, |
|
- #size-cells: Must be 0. |
|
If the PM domain is always-on, this property must be omitted. |
|
|
|
|
|
Example: |
|
|
|
This shows a subset of the r8a7740 PM domain hierarchy, containing the |
|
C5 "always-on" domain, 2 of its subdomains (A4S and A4SU), and the A3SP domain, |
|
which is a subdomain of A4S. |
|
|
|
sysc: system-controller@e6180000 { |
|
compatible = "renesas,sysc-r8a7740", "renesas,sysc-rmobile"; |
|
reg = <0xe6180000 0x8000>, <0xe6188000 0x8000>; |
|
|
|
pm-domains { |
|
pd_c5: c5 { |
|
#address-cells = <1>; |
|
#size-cells = <0>; |
|
#power-domain-cells = <0>; |
|
|
|
pd_a4s: a4s@10 { |
|
reg = <10>; |
|
#address-cells = <1>; |
|
#size-cells = <0>; |
|
#power-domain-cells = <0>; |
|
|
|
pd_a3sp: a3sp@11 { |
|
reg = <11>; |
|
#power-domain-cells = <0>; |
|
}; |
|
}; |
|
|
|
pd_a4su: a4su@20 { |
|
reg = <20>; |
|
#power-domain-cells = <0>; |
|
}; |
|
}; |
|
}; |
|
}; |
|
|
|
|
|
== PM Domain Consumers == |
|
|
|
Hardware blocks belonging to a PM domain should contain a "power-domains" |
|
property that is a phandle pointing to the corresponding PM domain node. |
|
|
|
Example: |
|
|
|
tpu: pwm@e6600000 { |
|
compatible = "renesas,tpu-r8a7740", "renesas,tpu"; |
|
reg = <0xe6600000 0x100>; |
|
clocks = <&mstp3_clks R8A7740_CLK_TPU0>; |
|
power-domains = <&pd_a3sp>; |
|
#pwm-cells = <3>; |
|
};
|
|
|