mirror of https://github.com/Qortal/Brooklyn
You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
74 lines
2.1 KiB
74 lines
2.1 KiB
# SPDX-License-Identifier: GPL-2.0-only |
|
menu "Amlogic SoC drivers" |
|
|
|
config MESON_CANVAS |
|
tristate "Amlogic Meson Canvas driver" |
|
depends on ARCH_MESON || COMPILE_TEST |
|
default n |
|
help |
|
Say yes to support the canvas IP for Amlogic SoCs. |
|
|
|
config MESON_CLK_MEASURE |
|
tristate "Amlogic Meson SoC Clock Measure driver" |
|
depends on ARCH_MESON || COMPILE_TEST |
|
default ARCH_MESON |
|
select REGMAP_MMIO |
|
help |
|
Say yes to support of Measuring a set of internal SoC clocks |
|
from the debugfs interface. |
|
|
|
config MESON_GX_SOCINFO |
|
bool "Amlogic Meson GX SoC Information driver" |
|
depends on (ARM64 && ARCH_MESON) || COMPILE_TEST |
|
default ARCH_MESON |
|
select SOC_BUS |
|
help |
|
Say yes to support decoding of Amlogic Meson GX SoC family |
|
information about the type, package and version. |
|
|
|
config MESON_GX_PM_DOMAINS |
|
tristate "Amlogic Meson GX Power Domains driver" |
|
depends on ARCH_MESON || COMPILE_TEST |
|
depends on PM && OF |
|
default ARCH_MESON |
|
select PM_GENERIC_DOMAINS |
|
select PM_GENERIC_DOMAINS_OF |
|
help |
|
Say yes to expose Amlogic Meson GX Power Domains as |
|
Generic Power Domains. |
|
|
|
config MESON_EE_PM_DOMAINS |
|
tristate "Amlogic Meson Everything-Else Power Domains driver" |
|
depends on ARCH_MESON || COMPILE_TEST |
|
depends on PM && OF |
|
default ARCH_MESON |
|
select PM_GENERIC_DOMAINS |
|
select PM_GENERIC_DOMAINS_OF |
|
help |
|
Say yes to expose Amlogic Meson Everything-Else Power Domains as |
|
Generic Power Domains. |
|
|
|
config MESON_SECURE_PM_DOMAINS |
|
tristate "Amlogic Meson Secure Power Domains driver" |
|
depends on (ARCH_MESON || COMPILE_TEST) && MESON_SM |
|
depends on PM && OF |
|
depends on HAVE_ARM_SMCCC |
|
default ARCH_MESON |
|
select PM_GENERIC_DOMAINS |
|
select PM_GENERIC_DOMAINS_OF |
|
help |
|
Support for the power controller on Amlogic A1/C1 series. |
|
Say yes to expose Amlogic Meson Secure Power Domains as Generic |
|
Power Domains. |
|
|
|
config MESON_MX_SOCINFO |
|
bool "Amlogic Meson MX SoC Information driver" |
|
depends on (ARM && ARCH_MESON) || COMPILE_TEST |
|
default ARCH_MESON |
|
select SOC_BUS |
|
help |
|
Say yes to support decoding of Amlogic Meson6, Meson8, |
|
Meson8b and Meson8m2 SoC family information about the type |
|
and version. |
|
|
|
endmenu
|
|
|