ACPI Fan Performance States |
|
=========================== |
|
|
|
When the optional _FPS object is present under an ACPI device representing a |
|
fan (for example, PNP0C0B or INT3404), the ACPI fan driver creates additional |
|
"state*" attributes in the sysfs directory of the ACPI device in question. |
|
These attributes list properties of fan performance states. |
|
|
|
For more information on _FPS refer to the ACPI specification at: |
|
|
|
http://uefi.org/specifications |
|
|
|
For instance, the contents of the INT3404 ACPI device sysfs directory |
|
may look as follows:: |
|
|
|
$ ls -l /sys/bus/acpi/devices/INT3404:00/ |
|
total 0 |
|
... |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state0 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state1 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state10 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state11 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state2 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state3 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state4 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state5 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state6 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state7 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state8 |
|
-r--r--r-- 1 root root 4096 Dec 13 20:38 state9 |
|
-r--r--r-- 1 root root 4096 Dec 13 01:00 status |
|
... |
|
|
|
where each of the "state*" files represents one performance state of the fan |
|
and contains a colon-separated list of 5 integer numbers (fields) with the |
|
following interpretation:: |
|
|
|
control_percent:trip_point_index:speed_rpm:noise_level_mdb:power_mw |
|
|
|
* ``control_percent``: The percent value to be used to set the fan speed to a |
|
specific level using the _FSL object (0-100). |
|
|
|
* ``trip_point_index``: The active cooling trip point number that corresponds |
|
to this performance state (0-9). |
|
|
|
* ``speed_rpm``: Speed of the fan in rotations per minute. |
|
|
|
* ``noise_level_mdb``: Audible noise emitted by the fan in this state in |
|
millidecibels. |
|
|
|
* ``power_mw``: Power draw of the fan in this state in milliwatts. |
|
|
|
For example:: |
|
|
|
$cat /sys/bus/acpi/devices/INT3404:00/state1 |
|
25:0:3200:12500:1250 |
|
|
|
When a given field is not populated or its value provided by the platform |
|
firmware is invalid, the "not-defined" string is shown instead of the value.
|
|
|