Kernel driver w83l786ng |
|
======================= |
|
|
|
Supported chips: |
|
|
|
* Winbond W83L786NG/W83L786NR |
|
|
|
Prefix: 'w83l786ng' |
|
|
|
Addresses scanned: I2C 0x2e - 0x2f |
|
|
|
Datasheet: http://www.winbond-usa.com/products/winbond_products/pdfs/PCIC/W83L786NRNG09.pdf |
|
|
|
Author: Kevin Lo <[email protected]> |
|
|
|
|
|
Module Parameters |
|
----------------- |
|
|
|
* reset boolean |
|
(default 0) |
|
|
|
Use 'reset=1' to reset the chip (via index 0x40, bit 7). The default |
|
behavior is no chip reset to preserve BIOS settings |
|
|
|
|
|
Description |
|
----------- |
|
|
|
This driver implements support for Winbond W83L786NG/W83L786NR chips. |
|
|
|
The driver implements two temperature sensors, two fan rotation speed |
|
sensors, and three voltage sensors. |
|
|
|
Temperatures are measured in degrees Celsius and measurement resolution is 1 |
|
degC for temp1 and temp2. |
|
|
|
Fan rotation speeds are reported in RPM (rotations per minute). Fan readings |
|
can be divided by a programmable divider (1, 2, 4, 8, 16, 32, 64 |
|
or 128 for fan 1/2) to give the readings more range or accuracy. |
|
|
|
Voltage sensors (also known as IN sensors) report their values in millivolts. |
|
An alarm is triggered if the voltage has crossed a programmable minimum |
|
or maximum limit. |
|
|
|
/sys files |
|
---------- |
|
|
|
pwm[1-2] |
|
- this file stores PWM duty cycle or DC value (fan speed) in range: |
|
|
|
0 (stop) to 255 (full) |
|
pwm[1-2]_enable |
|
- this file controls mode of fan/temperature control: |
|
|
|
* 0 Manual Mode |
|
* 1 Thermal Cruise |
|
* 2 Smart Fan II |
|
* 4 FAN_SET |
|
pwm[1-2]_mode |
|
- Select PWM of DC mode |
|
|
|
* 0 DC |
|
* 1 PWM |
|
tolerance[1-2] |
|
- Value in degrees of Celsius (degC) for +- T
|
|
|