Binding for Broadcom BCM6328 High Speed SPI controller |
|
|
|
Required properties: |
|
- compatible: must contain of "brcm,bcm6328-hsspi". |
|
- reg: Base address and size of the controllers memory area. |
|
- interrupts: Interrupt for the SPI block. |
|
- clocks: phandles of the SPI clock and the PLL clock. |
|
- clock-names: must be "hsspi", "pll". |
|
- #address-cells: <1>, as required by generic SPI binding. |
|
- #size-cells: <0>, also as required by generic SPI binding. |
|
|
|
Optional properties: |
|
- num-cs: some controllers have less than 8 cs signals. Defaults to 8 |
|
if absent. |
|
|
|
Child nodes as per the generic SPI binding. |
|
|
|
Example: |
|
|
|
spi@10001000 { |
|
compatible = "brcm,bcm6328-hsspi"; |
|
reg = <0x10001000 0x600>; |
|
|
|
interrupts = <29>; |
|
|
|
clocks = <&clkctl 9>, <&hsspi_pll>; |
|
clock-names = "hsspi", "pll"; |
|
|
|
num-cs = <2>; |
|
|
|
#address-cells = <1>; |
|
#size-cells = <0>; |
|
};
|
|
|