RPMH RSC: |
|
------------ |
|
|
|
Resource Power Manager Hardened (RPMH) is the mechanism for communicating with |
|
the hardened resource accelerators on Qualcomm SoCs. Requests to the resources |
|
can be written to the Trigger Command Set (TCS) registers and using a (addr, |
|
val) pair and triggered. Messages in the TCS are then sent in sequence over an |
|
internal bus. |
|
|
|
The hardware block (Direct Resource Voter or DRV) is a part of the h/w entity |
|
(Resource State Coordinator a.k.a RSC) that can handle multiple sleep and |
|
active/wake resource requests. Multiple such DRVs can exist in a SoC and can |
|
be written to from Linux. The structure of each DRV follows the same template |
|
with a few variations that are captured by the properties here. |
|
|
|
A TCS may be triggered from Linux or triggered by the F/W after all the CPUs |
|
have powered off to facilitate idle power saving. TCS could be classified as - |
|
|
|
ACTIVE /* Triggered by Linux */ |
|
SLEEP /* Triggered by F/W */ |
|
WAKE /* Triggered by F/W */ |
|
CONTROL /* Triggered by F/W */ |
|
|
|
The order in which they are described in the DT, should match the hardware |
|
configuration. |
|
|
|
Requests can be made for the state of a resource, when the subsystem is active |
|
or idle. When all subsystems like Modem, GPU, CPU are idle, the resource state |
|
will be an aggregate of the sleep votes from each of those subsystems. Clients |
|
may request a sleep value for their shared resources in addition to the active |
|
mode requests. |
|
|
|
Properties: |
|
|
|
- compatible: |
|
Usage: required |
|
Value type: <string> |
|
Definition: Should be "qcom,rpmh-rsc". |
|
|
|
- reg: |
|
Usage: required |
|
Value type: <prop-encoded-array> |
|
Definition: The first register specifies the base address of the |
|
DRV(s). The number of DRVs in the dependent on the RSC. |
|
The tcs-offset specifies the start address of the |
|
TCS in the DRVs. |
|
|
|
- reg-names: |
|
Usage: required |
|
Value type: <string> |
|
Definition: Maps the register specified in the reg property. Must be |
|
"drv-0", "drv-1", "drv-2" etc and "tcs-offset". The |
|
|
|
- interrupts: |
|
Usage: required |
|
Value type: <prop-encoded-interrupt> |
|
Definition: The interrupt that trips when a message complete/response |
|
is received for this DRV from the accelerators. |
|
|
|
- qcom,drv-id: |
|
Usage: required |
|
Value type: <u32> |
|
Definition: The id of the DRV in the RSC block that will be used by |
|
this controller. |
|
|
|
- qcom,tcs-config: |
|
Usage: required |
|
Value type: <prop-encoded-array> |
|
Definition: The tuple defining the configuration of TCS. |
|
Must have 2 cells which describe each TCS type. |
|
<type number_of_tcs>. |
|
The order of the TCS must match the hardware |
|
configuration. |
|
- Cell #1 (TCS Type): TCS types to be specified - |
|
ACTIVE_TCS |
|
SLEEP_TCS |
|
WAKE_TCS |
|
CONTROL_TCS |
|
- Cell #2 (Number of TCS): <u32> |
|
|
|
- label: |
|
Usage: optional |
|
Value type: <string> |
|
Definition: Name for the RSC. The name would be used in trace logs. |
|
|
|
Drivers that want to use the RSC to communicate with RPMH must specify their |
|
bindings as child nodes of the RSC controllers they wish to communicate with. |
|
|
|
Example 1: |
|
|
|
For a TCS whose RSC base address is is 0x179C0000 and is at a DRV id of 2, the |
|
register offsets for DRV2 start at 0D00, the register calculations are like |
|
this - |
|
DRV0: 0x179C0000 |
|
DRV2: 0x179C0000 + 0x10000 = 0x179D0000 |
|
DRV2: 0x179C0000 + 0x10000 * 2 = 0x179E0000 |
|
TCS-OFFSET: 0xD00 |
|
|
|
apps_rsc: rsc@179c0000 { |
|
label = "apps_rsc"; |
|
compatible = "qcom,rpmh-rsc"; |
|
reg = <0x179c0000 0x10000>, |
|
<0x179d0000 0x10000>, |
|
<0x179e0000 0x10000>; |
|
reg-names = "drv-0", "drv-1", "drv-2"; |
|
interrupts = <GIC_SPI 3 IRQ_TYPE_LEVEL_HIGH>, |
|
<GIC_SPI 4 IRQ_TYPE_LEVEL_HIGH>, |
|
<GIC_SPI 5 IRQ_TYPE_LEVEL_HIGH>; |
|
qcom,tcs-offset = <0xd00>; |
|
qcom,drv-id = <2>; |
|
qcom,tcs-config = <ACTIVE_TCS 2>, |
|
<SLEEP_TCS 3>, |
|
<WAKE_TCS 3>, |
|
<CONTROL_TCS 1>; |
|
}; |
|
|
|
Example 2: |
|
|
|
For a TCS whose RSC base address is 0xAF20000 and is at DRV id of 0, the |
|
register offsets for DRV0 start at 01C00, the register calculations are like |
|
this - |
|
DRV0: 0xAF20000 |
|
TCS-OFFSET: 0x1C00 |
|
|
|
disp_rsc: rsc@af20000 { |
|
label = "disp_rsc"; |
|
compatible = "qcom,rpmh-rsc"; |
|
reg = <0xaf20000 0x10000>; |
|
reg-names = "drv-0"; |
|
interrupts = <GIC_SPI 129 IRQ_TYPE_LEVEL_HIGH>; |
|
qcom,tcs-offset = <0x1c00>; |
|
qcom,drv-id = <0>; |
|
qcom,tcs-config = <ACTIVE_TCS 0>, |
|
<SLEEP_TCS 1>, |
|
<WAKE_TCS 1>, |
|
<CONTROL_TCS 0>; |
|
};
|
|
|