# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) |
|
%YAML 1.2 |
|
--- |
|
$id: http://devicetree.org/schemas/reset/fsl,imx7-src.yaml# |
|
$schema: http://devicetree.org/meta-schemas/core.yaml# |
|
|
|
title: Freescale i.MX7 System Reset Controller |
|
|
|
maintainers: |
|
- Andrey Smirnov <[email protected]> |
|
|
|
description: | |
|
The system reset controller can be used to reset various set of |
|
peripherals. Device nodes that need access to reset lines should |
|
specify them as a reset phandle in their corresponding node as |
|
specified in reset.txt. |
|
|
|
For list of all valid reset indices see |
|
<dt-bindings/reset/imx7-reset.h> for i.MX7, |
|
<dt-bindings/reset/imx8mq-reset.h> for i.MX8MQ, i.MX8MM and i.MX8MN, |
|
<dt-bindings/reset/imx8mp-reset.h> for i.MX8MP. |
|
|
|
properties: |
|
compatible: |
|
oneOf: |
|
- items: |
|
- enum: |
|
- fsl,imx7d-src |
|
- fsl,imx8mq-src |
|
- fsl,imx8mp-src |
|
- const: syscon |
|
- items: |
|
- enum: |
|
- fsl,imx8mm-src |
|
- fsl,imx8mn-src |
|
- const: fsl,imx8mq-src |
|
- const: syscon |
|
|
|
reg: |
|
maxItems: 1 |
|
|
|
interrupts: |
|
maxItems: 1 |
|
|
|
'#reset-cells': |
|
const: 1 |
|
|
|
required: |
|
- compatible |
|
- reg |
|
- interrupts |
|
- '#reset-cells' |
|
|
|
additionalProperties: false |
|
|
|
examples: |
|
- | |
|
#include <dt-bindings/interrupt-controller/arm-gic.h> |
|
|
|
reset-controller@30390000 { |
|
compatible = "fsl,imx7d-src", "syscon"; |
|
reg = <0x30390000 0x2000>; |
|
interrupts = <GIC_SPI 89 IRQ_TYPE_LEVEL_HIGH>; |
|
#reset-cells = <1>; |
|
};
|
|
|