.. SPDX-License-Identifier: GPL-2.0 |
|
|
|
Kernel driver pli1209bc |
|
======================= |
|
|
|
Supported chips: |
|
|
|
* Digital Supervisor PLI1209BC |
|
|
|
Prefix: 'pli1209bc' |
|
|
|
Addresses scanned: 0x50 - 0x5F |
|
|
|
Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf |
|
|
|
Authors: |
|
- Marcello Sylvester Bauer <[email protected]> |
|
|
|
Description |
|
----------- |
|
|
|
The Vicor PLI1209BC is an isolated digital power system supervisor that provides |
|
a communication interface between a host processor and one Bus Converter Module |
|
(BCM). The PLI communicates with a system controller via a PMBus compatible |
|
interface over an isolated UART interface. Through the PLI, the host processor |
|
can configure, set protection limits, and monitor the BCM. |
|
|
|
Sysfs entries |
|
------------- |
|
|
|
======================= ======================================================== |
|
in1_label "vin2" |
|
in1_input Input voltage. |
|
in1_rated_min Minimum rated input voltage. |
|
in1_rated_max Maximum rated input voltage. |
|
in1_max Maximum input voltage. |
|
in1_max_alarm Input voltage high alarm. |
|
in1_crit Critical input voltage. |
|
in1_crit_alarm Input voltage critical alarm. |
|
|
|
in2_label "vout2" |
|
in2_input Output voltage. |
|
in2_rated_min Minimum rated output voltage. |
|
in2_rated_max Maximum rated output voltage. |
|
in2_alarm Output voltage alarm |
|
|
|
curr1_label "iin2" |
|
curr1_input Input current. |
|
curr1_max Maximum input current. |
|
curr1_max_alarm Maximum input current high alarm. |
|
curr1_crit Critical input current. |
|
curr1_crit_alarm Input current critical alarm. |
|
|
|
curr2_label "iout2" |
|
curr2_input Output current. |
|
curr2_crit Critical output current. |
|
curr2_crit_alarm Output current critical alarm. |
|
curr2_max Maximum output current. |
|
curr2_max_alarm Output current high alarm. |
|
|
|
power1_label "pin2" |
|
power1_input Input power. |
|
power1_alarm Input power alarm. |
|
|
|
power2_label "pout2" |
|
power2_input Output power. |
|
power2_rated_max Maximum rated output power. |
|
|
|
temp1_input Die temperature. |
|
temp1_alarm Die temperature alarm. |
|
temp1_max Maximum die temperature. |
|
temp1_max_alarm Die temperature high alarm. |
|
temp1_crit Critical die temperature. |
|
temp1_crit_alarm Die temperature critical alarm. |
|
======================= ========================================================
|
|
|