Kernel Driver IBMPOWERNV |
|
======================== |
|
|
|
Supported systems: |
|
|
|
* Any recent IBM P servers based on POWERNV platform |
|
|
|
Author: Neelesh Gupta |
|
|
|
Description |
|
----------- |
|
|
|
This driver implements reading the platform sensors data like temperature/fan/ |
|
voltage/power for 'POWERNV' platform. |
|
|
|
The driver uses the platform device infrastructure. It probes the device tree |
|
for sensor devices during the __init phase and registers them with the 'hwmon'. |
|
'hwmon' populates the 'sysfs' tree having attribute files, each for a given |
|
sensor type and its attribute data. |
|
|
|
All the nodes in the DT appear under "/ibm,opal/sensors" and each valid node in |
|
the DT maps to an attribute file in 'sysfs'. The node exports unique 'sensor-id' |
|
which the driver uses to make an OPAL call to the firmware. |
|
|
|
Usage notes |
|
----------- |
|
The driver is built statically with the kernel by enabling the config |
|
CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'. |
|
|
|
Sysfs attributes |
|
---------------- |
|
|
|
======================= ======================================================= |
|
fanX_input Measured RPM value. |
|
fanX_min Threshold RPM for alert generation. |
|
fanX_fault - 0: No fail condition |
|
- 1: Failing fan |
|
|
|
tempX_input Measured ambient temperature. |
|
tempX_max Threshold ambient temperature for alert generation. |
|
tempX_highest Historical maximum temperature |
|
tempX_lowest Historical minimum temperature |
|
tempX_enable Enable/disable all temperature sensors belonging to the |
|
sub-group. In POWER9, this attribute corresponds to |
|
each OCC. Using this attribute each OCC can be asked to |
|
disable/enable all of its temperature sensors. |
|
|
|
- 1: Enable |
|
- 0: Disable |
|
|
|
inX_input Measured power supply voltage (millivolt) |
|
inX_fault - 0: No fail condition. |
|
- 1: Failing power supply. |
|
inX_highest Historical maximum voltage |
|
inX_lowest Historical minimum voltage |
|
inX_enable Enable/disable all voltage sensors belonging to the |
|
sub-group. In POWER9, this attribute corresponds to |
|
each OCC. Using this attribute each OCC can be asked to |
|
disable/enable all of its voltage sensors. |
|
|
|
- 1: Enable |
|
- 0: Disable |
|
|
|
powerX_input Power consumption (microWatt) |
|
powerX_input_highest Historical maximum power |
|
powerX_input_lowest Historical minimum power |
|
powerX_enable Enable/disable all power sensors belonging to the |
|
sub-group. In POWER9, this attribute corresponds to |
|
each OCC. Using this attribute each OCC can be asked to |
|
disable/enable all of its power sensors. |
|
|
|
- 1: Enable |
|
- 0: Disable |
|
|
|
currX_input Measured current (milliampere) |
|
currX_highest Historical maximum current |
|
currX_lowest Historical minimum current |
|
currX_enable Enable/disable all current sensors belonging to the |
|
sub-group. In POWER9, this attribute corresponds to |
|
each OCC. Using this attribute each OCC can be asked to |
|
disable/enable all of its current sensors. |
|
|
|
- 1: Enable |
|
- 0: Disable |
|
|
|
energyX_input Cumulative energy (microJoule) |
|
======================= =======================================================
|
|
|