title: NTC thermistor temperature sensors |
|
|
|
maintainers: |
|
- Naveen Krishna Chatradhi <[email protected]> |
|
- Linus Walleij <[email protected]> |
|
|
|
description: | |
|
Thermistors with negative temperature coefficient (NTC) are resistors that |
|
vary in resistance in an often non-linear way in relation to temperature. |
|
The negative temperature coefficient means that the resistance decreases |
|
as the temperature rises. Since the relationship between resistance and |
|
temperature is non-linear, software drivers most often need to use a look |
|
up table and interpolation to get from resistance to temperature. |
|
|
|
When used in practice, a thermistor is often connected between ground, a |
|
pull-up resistor or/and a pull-down resistor and a fixed voltage like this: |
|
|
|
+ e.g. 5V = pull-up voltage (puv) |
|
| |
|
+-+ |
|
| | |
|
| | Pull-up resistor |
|
| | (puo) |
|
+-+ |
|
|-------------------------o |
|
+-+ | ^ |
|
| |/ | |
|
| / | |
|
|/| Thermistor | Measured voltage (mv) |
|
/ | | "connected ground" |
|
/| | | |
|
+-+ | |
|
|-------------------------o |
|
+-+ ^ |
|
| | | |
|
| | Pull-down resistor | Measured voltage (mv) |
|
| | (pdo) | "connected positive" |
|
+-+ | |
|
| | |
|
| v |
|
+ GND GND |
|
|
|
The arrangements of where we measure the voltage over the thermistor are |
|
called "connected ground" and "connected positive" and shall be understood as |
|
the cases when either pull-up or pull-down resistance is zero. |
|
|
|
If the pull-up resistance is 0 one end of the thermistor is connected to the |
|
positive voltage and we get the thermistor on top of a pull-down resistor |
|
and we take the measure between the thermistor and the pull-down resistor. |
|
|
|
Conversely if the pull-down resistance is zero, one end of the thermistor is |
|
connected to ground and we get the thermistor under the pull-up resistor |
|
and we take the measure between the pull-up resistor and the thermistor. |
|
|
|
We can use both pull-up and pull-down resistors at the same time, and then |
|
the figure illustrates where the voltage will be measured for the "connected |
|
ground" and "connected positive" cases. |
|
|
|
properties: |
|
$nodename: |
|
pattern: "^thermistor(.*)?$" |
|
|
|
compatible: |
|
oneOf: |
|
- const: epcos,b57330v2103 |
|
- const: epcos,b57891s0103 |
|
- const: murata,ncp15wb473 |
|
- const: murata,ncp18wb473 |
|
- const: murata,ncp21wb473 |
|
- const: murata,ncp03wb473 |
|
- const: murata,ncp15wl333 |
|
- const: murata,ncp03wf104 |
|
- const: murata,ncp15xh103 |
|
- const: samsung,1404-001221 |
|
# Deprecated "ntp," compatible strings |
|
- const: ntc,ncp15wb473 |
|
deprecated: true |
|
- const: ntc,ncp18wb473 |
|
deprecated: true |
|
- const: ntc,ncp21wb473 |
|
deprecated: true |
|
- const: ntc,ncp03wb473 |
|
deprecated: true |
|
- const: ntc,ncp15wl333 |
|
deprecated: true |
|
|
|
"#thermal-sensor-cells": |
|
description: Thermal sensor cells if used for thermal sensoring. |
|
const: 0 |
|
|
|
pullup-uv: |
|
$ref: /schemas/types.yaml#/definitions/uint32 |
|
description: Pull-up voltage in micro volts. Must always be specified. |
|
|
|
pullup-ohm: |
|
$ref: /schemas/types.yaml#/definitions/uint32 |
|
description: Pull-up resistance in ohms. Must always be specified, even |
|
if zero. |
|
|
|
pulldown-ohm: |
|
$ref: /schemas/types.yaml#/definitions/uint32 |
|
description: Pull-down resistance in ohms. Must always be specified, even |
|
if zero. |
|
|
|
connected-positive: |
|
$ref: /schemas/types.yaml#/definitions/flag |
|
description: Indicates how the thermistor is connected in series with |
|
a pull-up and/or a pull-down resistor. See the description above for |
|
an illustration. If this flag is NOT specified, the thermistor is assumed |
|
to be connected-ground, which usually means a pull-down resistance of |
|
zero but complex arrangements are possible. |
|
|
|
# See /schemas/iio/adc/adc.yaml |
|
io-channels: |
|
maxItems: 1 |
|
description: IIO ADC channel to read the voltage over the resistor. Must |
|
always be specified. |
|
|
|
required: |
|
- compatible |
|
- pullup-uv |
|
- pullup-ohm |
|
- pulldown-ohm |
|
- io-channels |
|
|
|
additionalProperties: false |
|
|
|
examples: |
|
- | |
|
thermistor0 { |
|
compatible = "murata,ncp18wb473"; |
|
io-channels = <&gpadc 0x06>; |
|
pullup-uv = <1800000>; |
|
pullup-ohm = <220000>; |
|
pulldown-ohm = <0>; |
|
#thermal-sensor-cells = <0>; |
|
};
|
|
|